Standard Distillation Fume Hoods

 

DS distillation fume hoodThe type DS- distillation fume hood is provided with a large face opening for setting up tall apparatus, distillation columns, etc., or it can be used as a bench type hood by simply adding a removable or fixed counter height work surface. Distillation hoods are available in lengths from 3’-0" to 100’-0" and may be customized to each user’s specific needs.

The DS- distillation fume hood is furnished with the following features:

  • The hood exterior is fabricated of either a special chemical resistant plastic (DS1-) or of 18 gauge, zinc-coated and bondarized steel with a chemical resistant enamel (DS2-) to match the supporting table frame.
  • The interior of the hood is made of 1/4" thick, special heat, solvent and reagent resistant composition stone that is treated with a chemical resistant, clear vinyl for added protection. Additional hood liners are available upon request, including a white modified resin/fiberglass, a fiberglass reinforced polyester (FRP), white polypropylene and stainless steel.
  • The fume hood baffles have three adjustable air flow dampers at the top, center and bottom for adjustment to light or heavy gases.
  • A vapor-proof incandescent light fixture is furnished for added visibility. (Two light fixtures are furnished in hoods 7’-0" and longer.)
  • Two vertically rising front sashes are furnished and glazed with 1/4" thick, laminated safety glass. The window sashes are counter balanced with lead weights for fingertip movement. (Optional sash stops are available to restrict the face opening during hood operation. The stops may be released for set-up purposes.)
  • A hood floor or counter top shall be furnished in 1" thick flat or 1-1/4" thick dished black epoxy resin. (Other materials are also available.)
  • A heavy duty table base (made of enameled steel in a heavy duty construction) is furnished to support the distillation hood.
  • If the hood is furnished with a blower, the blower can be enclosed within the hood ceiling or shipped separately. The blower housing and wheel are coated with a highly chemical resistant epoxy coating for extra protection against corrosion.

CLICK HERE TO VIEW SPECS   1    2

Typical DS1- and DS2- Fume Hoods

Catalog Number

 Overall Size L x H*

Face
Opening
w/ upper
30" H sash
fully raised

Exhaust
CFM @
100 FPM
face
velocity

Exhaust
S.P.

Standard
Exhaust
Blower
Included

Exterior Exterior

Plastic Metal

DS1-4B DS2-4B 48" 114"
7.3   SF
730 CFM
1/4" D8C
DS1-5B DS2-5B 60" 114"
9.7 SF
970 CFM
1/4" D9C
DS1-6B DS2-6B 72" 114"
12.8 SF
1280 CFM
3/8" KE-11
DS1-7B DS2-7B 84" 114"
14.5 SF
1450 CFM
1/4" KE-12
DS1-8B DS2-8B 96" 114"
16.9 SF
1690 CFM
1/4" KE-12
DS1-4 DS2-4 48" 101"
7.3 SF
730 CFM
1/4" None
DS1-5 DS2-5 60" 101"
9.7 SF
970 CFM
1/4" None
DS1-6 DS2-6 72" 101"
12.8 SF
1280 CFM
3/8" None
DS1-7 DS2-7 84" 101"
14.5 SF
1450 CFM
1/4" None
DS1-8 DS2-8 96" 101"
16.9 SF
1690 CFM
1/4" None
* Note:
Overall height when hood superstructure is installed on to the supporting table frame.
Note:
Blowers, where required, may be shipped either factory installed within the hood’s ceiling or separate from the hood superstructure.
Note:
A complete system, including exhaust duct work, may be furnished
Note:
The total CFM requirement and the standard blowers are based on the lower window sash being  closed and the upper sash being open during fume hood operation.

Optional Features (but not limited to):

Work Surface, Fixed or Removable
  • Cast epoxy resin, flat or dished
  • "Solid Bond" stainless steel
Service Fixtures
  • R400V remote control valve assembly with angled serrated hose connection. Specify Index.
  • R410V remote control water faucet with swivel goose and hose connection for use with either cold or hot water. Specify Index.
  • R410V-MIX remote control mixing faucet with swivel gooseneck and hose connection for use with hot and cold water.
  • Factory prepipe the service fixtures to either the upper or lower rear of the hood.
Cup Sinks
  • Polypropylene, panel or deck mounted
  • Chrome plated funnel cup sink, panel mounted
  • Stainless steel, deck mount
  • Epoxy resin sinks, deck mounted
Electrical Items
  • Duplex or single receptacles. Specify voltage and amperage required.
  • Motor starter or on/off switch for exhaust blower. Specify if single or three phase and voltage.
Light Fixtures
  • Two tube fluorescent light fixture (less bulbs).
  • Explosion-proof, 150-300 watt incandescent light fixture (less bulb).
Base Cabinets
  • Standard double cupboard cabinet
  • Acid storage cabinet with composition stone lining. (Vented doors and/or vent assembly to the hood’s work surface are optional.)
  • Solvent storage cabinet. (Vent assembly to the hood’s work surface is optional.)
Safety Guard Low Face Velocity Alarm
  • Complies with OSHA regulations
  • Factory installed and wired

 

 

 